Liquid Screed

1. Screed – flowing liquid or sand & cement (see below)
2. GS-UFH 14mm or 17mm PE-Xa pipe by the Engel process
3. GS-UFH tecto system board
4. GS-UFH edge isolation material profile with sealing skirt
5. Load bearing floor
6. Additional insulation
7. Damp membrane – to architects detail
8. Service void – optional

Note re Dimension :
INSULATION REQUIREMENTS MUST BE SPECIFIED FOR INDIVIDUAL PROJECTS ON GROUND FLOOR AND COMPLY WITH CURRENT BUILDING REGULATIONS

(h) Typical screed depth
Flowing liquid screed: 47mm Minimum – 60mm Optimum
Sand cement screed: 65mm – 75mm

Note:
SCREED SPECIFICATION AND DEPTHS SHOULD BE AGREED WITH STRUCTURAL ENGINEER BASED ON FLOOR CATEGORY AND LOADING REQUIREMENTS